Sime AL 41 Fault Code: Causes, Fixes & Repair Costs

What does the Sime AL 41 fault code mean?

The AL 41 code appears on Sime boilers when the burner flame has been lost six times in a row during the ignition sequence. After this sixth consecutive failed attempt to establish and hold a flame, the boiler locks out entirely and displays AL 41 to protect itself from further damage. This is a safety lockout — the boiler will not restart automatically and requires manual intervention. The root cause can range from a straightforward gas supply issue to a faulty component within the ignition or burner system, so the fault needs to be investigated carefully before simply resetting the boiler repeatedly.

Lockout — engineer likely May need a Gas Safe engineer 5 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Check your gas supply is active DIY safe

    Before anything else, confirm that other gas appliances in the property — such as a gas hob or gas fire — are working normally. If they are not, the fault is with your gas supply rather than the boiler itself: contact your gas supplier. Also check that the boiler's gas isolation valve (the handle on the pipe leading into the boiler) is in the open position — the handle should be in line with the pipe, not across it.

  2. Reset the boiler DIY safe

    Once you have confirmed the gas supply is on, press and hold the reset button (refer to your Sime boiler's user manual for the exact location) until the lockout indicator clears, then allow the boiler to attempt ignition. If it lights and runs normally, monitor it over the next hour or so. Do not reset the boiler more than two or three times in quick succession — repeated resets without finding the underlying cause can cause further damage and will not resolve the fault.

  3. Check the external flue terminal for obvious blockages DIY safe

    Go outside and visually inspect the flue outlet on the external wall. Look for bird nests, leaves, debris, or any build-up of ice in cold weather that could be restricting the exit of flue gases. Do not insert your hand or any tool into the flue. If you can see a clear obstruction at the terminal end and can safely remove it without touching the flue pipework itself, do so, then attempt a reset. If you are unsure or cannot safely access it, leave this to an engineer.

  4. Contact a Gas Safe registered engineer to inspect the ignition system Gas Safe engineer

    If the boiler continues to lock out with AL 41 after the above checks, the fault is almost certainly within a component that only a Gas Safe registered engineer may legally inspect, test, or replace. The engineer will measure gas inlet pressure, test the spark at the electrode, check the ionisation current from the flame sensor, and assess the condition of the gas valve. Do not attempt to access or adjust any of these components yourself.

  5. Engineer to inspect and clean or replace the burner Gas Safe engineer

    As part of the investigation, the engineer should inspect the burner for deposits, corrosion, or damage that could be disrupting combustion. A burner service or replacement may resolve the fault without needing to replace more expensive parts.

  6. Engineer to test and replace faulty components as needed Gas Safe engineer

    Depending on diagnosis, the engineer may replace the ignition electrode and lead, the flame sensing probe, or the gas valve. In rare cases the PCB may need to be tested and replaced. Only parts and labour carried out by a Gas Safe engineer will be covered by any remaining manufacturer warranty, and this work is a legal requirement under Gas Safety (Installation and Use) Regulations 1998.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £120–£380, depending on the underlying cause.

Frequently asked questions

Can I fix Sime AL 41 myself by resetting the boiler?

A single reset is worth trying once you have confirmed your gas supply is on and the flue terminal is unobstructed. However, if the boiler locks out again after one or two resets, resetting it further will not cure the underlying fault and may mask a safety issue. The AL 41 lockout specifically indicates that the flame failed to establish six times in a row, which points to a component fault — such as a worn electrode, a faulty flame sensor, or a gas valve problem — that requires a Gas Safe registered engineer to diagnose and repair legally.

How much does it cost to repair a Sime AL 41 fault in the UK?

For most households, the repair falls between £120 and £380, depending on which component has failed. Replacing an ignition electrode and lead is typically at the lower end (roughly £120–£180 including labour), while a gas valve replacement usually sits between £200 and £350 all in. If a PCB is at fault, costs can exceed £400–£500, though this is less common. Always obtain at least two quotes from Gas Safe registered engineers, and ask whether the diagnosis call-out fee is included in the repair price.

Why does my Sime boiler keep showing AL 41 every few days?

An intermittent or recurring AL 41 fault usually points to a component that is degrading rather than completely failed — most often a flame sensor that is becoming dirty or an electrode that is starting to wear. The boiler ignites successfully most of the time but drops the flame occasionally, eventually accumulating six consecutive failures and locking out. This pattern tends to worsen over time rather than self-resolve. Have a Gas Safe engineer inspect the ignition and sensing components sooner rather than later, as an intermittent fault is easier and cheaper to address before it becomes a complete failure.

Could a blocked condensate pipe cause AL 41 on a Sime boiler?

It is unlikely but not impossible. A blocked condensate pipe — which commonly freezes in very cold weather — causes most Sime boilers to display a different fault code related to condensate or water pressure. However, if a severe blockage causes the boiler to shut down abnormally mid-cycle, a flame-loss code can occasionally follow. If you notice the fault during a cold snap, check whether the condensate pipe (the plastic pipe that runs from the boiler to an external drain) is frozen and thaw it gently with warm (not boiling) water. If the boiler then restarts and runs normally, condensate was the culprit. If AL 41 persists, the cause lies elsewhere and an engineer is needed.

Affected models: Sime Brava One ErP, Sime Format, Sime Murelle, Sime Planet Dewy, Sime Friendly

Last reviewed 1 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Sime AL 41 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →