Vokera 04 Fault Code: Causes, Fixes & Repair Costs

What does the Vokera 04 fault code mean?

The Vokera A04 fault code indicates that the water pressure in your central heating system has dropped below the minimum level required for safe operation. Vokera boilers need a system pressure of between 1 and 1.5 bar when the boiler is switched off and cold. If the pressure sensor detects a reading below this threshold, the boiler will lock out and display code 04 or A04 to protect internal components. Note that on a small number of older Vokera models this code has been associated with an overheat or fan-related fault, so if the guidance below does not match what you are seeing, cross-reference with your specific model's manual. For the vast majority of Vokera boilers, however, A04 means low system water pressure.

Lockout — engineer likely Some DIY checks possible 8 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Check the pressure gauge on your boiler DIY safe

    Locate the pressure gauge on the front or underside of your Vokera boiler. With the boiler switched off and fully cooled, the needle should sit between 1 and 1.5 bar. If it reads below 1 bar, the system needs topping up. If the gauge already reads within the correct range, skip ahead to step 4, as the issue may be a faulty sensor rather than genuinely low pressure.

  2. Top up system pressure using the filling loop DIY safe

    Find the filling loop — this is typically a braided flexible hose with one or two valves located beneath the boiler. Slowly open the valve (or both valves if there are two) and watch the pressure gauge rise. Stop when it reaches approximately 1.2 bar. Close the filling loop valve(s) fully before doing anything else. Never overfill beyond 1.5 bar as this can cause the PRV to discharge.

  3. Bleed your radiators if they feel cool at the top DIY safe

    Trapped air can contribute to pressure fluctuations and reduced heating efficiency. Using a radiator bleed key, open each bleed valve slightly until water runs out steadily with no air bubbling. Have a cloth ready to catch drips. Once all radiators are bled, recheck the boiler pressure gauge and top up again if it has dropped below 1 bar.

  4. Reset the boiler DIY safe

    Once pressure is restored to the correct level, reset the boiler. On Vokera models with a selector dial, move the dial to the OFF/RESET position, wait a few seconds, then move it back to your preferred operating mode (hot water only, or heating and hot water). On models with a dedicated reset button, press and hold it for a few seconds until the boiler restarts. If the boiler fires up and runs normally, monitor the pressure gauge over the next week or so to check it remains stable.

  5. Check for visible leaks around the boiler and radiators DIY safe

    If the A04 code returns within a short period, carry out a visual inspection of pipework joints, radiator valves, and the area beneath and around the boiler. Look for damp patches, white limescale deposits, or rust staining — all of which can indicate a slow weeping joint. Also check outside your property for the boiler's overflow pipe; if water is dripping from it, the PRV may be discharging. Do not attempt to repair any leaks yourself — this requires a Gas Safe engineer.

  6. Do not continue repeatedly topping up — call a Gas Safe registered engineer Gas Safe engineer

    If pressure drops again within a few weeks of being topped up, or if the A04 code returns immediately after a reset, there is an underlying fault that needs professional diagnosis. This could be a leaking joint, a failed expansion vessel, a weeping PRV, or a faulty pressure sensor or flow switch. A Gas Safe registered engineer will carry out a full system pressure test, identify the source of the problem, and carry out any necessary repairs legally and safely.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £100–£380, depending on the underlying cause.

Frequently asked questions

Can I top up my Vokera boiler pressure myself?

Yes — re-pressurising via the filling loop is one of the few boiler tasks that is safe for a homeowner to carry out. Locate the filling loop beneath the boiler, slowly open the valve until the gauge reaches around 1.2 bar, then close the valve and reset the boiler. However, if the pressure drops repeatedly and the A04 code keeps coming back, stop topping up and call a Gas Safe engineer to find the root cause.

Why does my Vokera boiler keep losing pressure and showing A04?

If the fault code returns within a few weeks of being topped up, something is causing the system to lose water. The most common culprits are a slow leak at a pipe joint, radiator valve, or inside the boiler itself, a waterlogged expansion vessel that can no longer absorb pressure changes, or a pressure relief valve that is weeping and releasing water outside. A Gas Safe engineer can carry out a pressure test to pinpoint the source. Do not keep re-pressurising without investigating, as masking a leak can cause wider damage over time.

How much does it cost to fix a recurring A04 pressure fault on a Vokera boiler?

If a simple top-up resolves the issue, the fix costs nothing. For professional repairs, a PRV replacement typically costs around £100–£150 including labour, while replacing a faulty expansion vessel usually runs between £150 and £350. Leak repairs to pipework or radiator valves vary depending on access and the number of joints affected but commonly fall in the £100–£250 range. For rare cases where a water-damaged PCB needs replacing, costs can rise to £400–£500 — but this is uncommon for a straightforward pressure fault and would only arise if a significant leak had been left unaddressed for some time.

My Vokera boiler gauge shows the correct pressure but the A04 code is still on — why?

If the pressure gauge reads between 1 and 1.5 bar but A04 is still displayed, the pressure sensor or flow switch feeding information to the boiler's PCB is likely faulty and giving a false low-pressure reading. An engineer will check continuity across the flow switch and test the sensor. Either component can be replaced at a relatively modest cost compared to larger parts. It is also worth checking that the gauge itself is accurate, as mechanical gauges can stick or give misleading readings over time.

Affected models: Vokera Linea, Vokera Mynute, Vokera Easi-Heat, Vokera Compact, Vokera Vision, Vokera Unica, Vokera Syntesi, Vokera Ion

Last reviewed 8 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Vokera 04 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →