What does the Vokera 03 fault code mean?

The 03 code (displayed as A03 on some Vokera models) tells you the boiler has detected a problem with the flue fan — the component responsible for drawing fresh combustion air in and pushing waste gases safely out through the flue. When the boiler's control board doesn't receive the expected speed signal from the fan, or detects the fan isn't running correctly, it triggers a safety lockout to prevent unvented flue gases from accumulating. On older Vokera Linea models with a metal pump-proving switch, the same code can occasionally appear even though the fan itself is fine — the switch is the real culprit. Because a faulty fan is a potential safety risk, the boiler will not restart until the underlying fault is resolved.

Lockout — engineer likely May need a Gas Safe engineer 6 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Check that nothing is blocking the flue terminal outside DIY safe

    Go outside and visually inspect the flue outlet and, where accessible, the air intake terminal. Look for bird nests, leaves, debris, or anything physically blocking the opening. Do not reach into the flue — simply clear any obvious external obstruction and make sure the terminal guard (if fitted) is intact. If the flue is high up or on a roof, do not attempt to access it yourself.

  2. Listen to the boiler when it tries to start DIY safe

    Stand near the boiler and initiate a heat demand (turn up the thermostat). You should hear the fan spin up before the burner fires. If you hear nothing at all, the fan may not be receiving power. If you hear a grinding, rattling, or intermittent whirring, the fan motor or its bearings are likely failing. Note what you hear and pass this information to your engineer — it helps narrow the diagnosis.

  3. Reset the boiler (up to twice) DIY safe

    Press and hold the reset button (marked R on most models) for 3–5 seconds until the fault code stops flashing, then release. On selector-dial models, turn the dial to the reset or OFF/RESET position and hold for a few seconds. Allow the boiler a full start-up cycle before judging whether the code has cleared. Repeat once more if the first attempt fails. Do not reset more than two or three times in quick succession — repeated resets without fixing the root cause can damage the ignition components.

  4. Call a Gas Safe registered engineer to inspect and repair the fan and associated components Gas Safe engineer

    If the fault code returns after resetting, a qualified engineer needs to attend. They will test the fan motor, wiring, and tachometer signal with a multimeter; inspect the air pressure switch and its sensing tube; check the flue for internal restrictions; and — only if all other components test correctly — assess the PCB. On older Linea models, they should also check the pump proving switch. The most common outcome is fan replacement, which is generally more cost-effective as a complete unit swap rather than a partial repair.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £180–£350, depending on the underlying cause.

Frequently asked questions

Is the Vokera 03 fault code dangerous?

It can be, which is exactly why the boiler locks itself out when it detects the problem. If the fan isn't working properly, combustion gases including carbon monoxide may not be safely vented. Do not attempt to override the lockout or repeatedly reset the boiler hoping it will clear on its own — get a Gas Safe engineer to diagnose the cause before using the boiler again.

My Vokera keeps showing the 03 code but then clears itself — should I be worried?

An intermittent 03 code that resets itself is a warning sign, not reassurance. It typically points to a fan that is on its way out, a marginal wiring connection, or a partly blocked flue — any of which can worsen without notice. Book an engineer check sooner rather than later; intermittent faults are often cheaper to fix than a full breakdown later.

How much does it cost to fix a Vokera 03 fault code in the UK?

For most homeowners, the repair involves replacing the fan, which typically costs £200–£300 including parts and labour. An air pressure switch replacement is usually around £150–£200 all in. If the PCB turns out to be the fault, costs rise significantly — often £400–£600 — but a competent engineer should only reach that conclusion after testing all other components first with a multimeter. Always insist the engineer diagnoses the specific failed part before authorising a PCB replacement.

Is it worth repairing a Vokera boiler showing the 03 code, or should I replace it?

If the boiler is under seven years old and the fan is the only worn component, repair is usually the right call. If your Vokera is older and the engineer finds two or more parts showing significant wear — for example, the fan and the pump or heat exchanger — the combined repair bill can approach half the cost of a new boiler. In that scenario, investing in a new boiler with a manufacturer warranty is often the smarter long-term choice.

Affected models: Vokera Compact 29a, Vokera Linea, Vokera Mynute, Vokera Vision, Vokera Easi-Heat, Vokera Unica

Last reviewed 8 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Vokera 03 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →