Vokera 01 Fault Code: Causes, Fixes & Repair Costs

What does the Vokera 01 fault code mean?

The Vokera A01 fault code (also displayed as fault code 10 on some Linea models) means the boiler attempted to light the burner after a heat demand but failed to establish a flame within the expected timeframe. As a safety precaution, the control board shuts the boiler down to prevent unburned gas from accumulating. The boiler will not restart until the underlying cause is addressed and the unit is reset. In plain terms: the boiler tried to ignite, got no confirmation of a flame, and locked out.

Lockout — engineer likely Some DIY checks possible May need a Gas Safe engineer 7 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Check your gas supply and meter DIY safe

    Before doing anything else, confirm that other gas appliances in your home — a gas hob, gas fire, or gas oven — are working. If nothing gas-powered is working, you likely have a supply issue: check that the gas isolation valve (the lever on the incoming gas pipe, usually near the meter) is in the open position (inline with the pipe). If you have a prepayment meter, check your credit balance immediately. If neighbours are also without gas, contact your gas network operator.

  2. Check and top up boiler pressure if needed DIY safe

    Look at the pressure gauge on your Vokera boiler — it should read between 1 and 1.5 bar when the system is cold. If it reads below 1 bar, top up the pressure using the filling loop (usually a flexible silver braided hose with one or two valves beneath the boiler). Open the valve(s) slowly, watch the gauge, and close them again once you reach about 1.2 bar. Never pressurise above 1.5 bar. If the pressure drops again quickly after topping up, you may have a leak and should call an engineer.

  3. Thaw a frozen condensate pipe if the weather is cold DIY safe

    If outdoor temperatures are below freezing, your condensate pipe — the white plastic pipe that exits the boiler and runs outside — may be frozen. You can pour warm (not boiling) water over the external section of the pipe, or wrap it with a warm damp cloth. Once thawed, reset the boiler. Consider lagging the pipe to prevent a recurrence.

  4. Reset the boiler (once or twice only) DIY safe

    Once you have completed the checks above, wait at least two minutes before attempting a reset. On Vokera models with a dedicated reset button (such as the Mynute or Easi-Heat), press and hold the button labelled 'R' for approximately 3–5 seconds until the fault code stops flashing, then release and allow the boiler to attempt a restart. On dial-operated models such as the Linea or Compact, turn the selector dial to the RESET or OFF position, hold for a few seconds, then return it to the normal operating position. Do not reset the boiler more than two or three times in total — repeated resets without fixing the root cause can damage components.

  5. Have a Gas Safe engineer inspect the ignition components Gas Safe engineer

    If the boiler locks out again after resetting, a Gas Safe registered engineer should carry out a full inspection. They will typically start by testing the flame sensor to confirm it is accurately detecting — or failing to detect — a flame. Next they will check the ignition electrode for wear and the ignition lead for continuity and insulation integrity using a multimeter. Both components can be replaced at relatively modest cost if found to be defective.

  6. Have the gas valve tested or replaced if ignition components are sound Gas Safe engineer

    If the electrode, lead, and flame sensor are all in order, the engineer's attention will turn to the gas valve. They will test whether the valve is opening correctly when signalled to do so. A faulty gas valve must only be handled by a Gas Safe engineer and should be replaced rather than repaired.

  7. Have the PCB assessed as a last resort Gas Safe engineer

    If all other components have been ruled out, the PCB may be sending incorrect ignition signals or misreading flame sensor feedback. An engineer can test board outputs with a multimeter. Given that PCB replacement on a Vokera boiler can cost several hundred pounds, it is worth asking the engineer whether the age and overall condition of the boiler makes replacement more economical than a PCB repair at this stage.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £150–£350, depending on the underlying cause.

Frequently asked questions

Can I fix a Vokera A01 fault myself?

You can safely carry out a handful of checks — confirming the gas supply is on, checking a prepayment meter has credit, topping up system pressure to 1–1.2 bar, thawing a frozen condensate pipe in cold weather, and resetting the boiler once or twice. Beyond that, any work on the ignition components, gas valve, or PCB must be carried out by a Gas Safe registered engineer. It is a legal requirement in the UK that gas work is performed by a qualified and registered professional.

Why does my Vokera boiler keep showing A01 even after I reset it?

If the A01 fault code returns each time you reset the boiler, a straightforward reset is not going to solve the underlying problem. The most common reasons for a repeat A01 are a worn ignition electrode, a damaged ignition lead, or a faulty flame sensor. Less commonly the gas valve or PCB is at fault. Stop resetting the boiler after two or three attempts and arrange for a Gas Safe engineer to diagnose and repair it — repeated resets without a fix can cause additional wear.

My boiler shows fault code 10, not A01 — is it the same problem?

Yes. On Vokera Linea models the same ignition failure fault is typically displayed as code 10 rather than A01. The meaning, causes, and recommended fixes are identical. If your Vokera model shows a numeric code you do not recognise, always cross-reference with your boiler's manual, as code numbering can vary slightly between models and production years.

How much does it cost to fix a Vokera A01 fault?

Most A01 repairs fall in the range of £150–£350, which typically covers a Gas Safe engineer's call-out, diagnosis, and replacement of the ignition electrode or lead — the most common causes. A gas valve replacement will usually sit toward the higher end of that range. PCB replacement is the expensive exception: parts alone can run to £200–£300 or more, and with labour the total can exceed £450–£500. On an older Vokera boiler, it is worth getting a frank assessment from your engineer about whether a PCB repair makes financial sense versus investing in a new boiler.

Affected models: Vokera Mynute, Vokera Easi-Heat, Vokera Compact, Vokera Compact A, Vokera Linea (displays as code 10), Vokera Turbomax, Vokera Unica

Last reviewed 8 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Vokera 01 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →