Biasi E19 Fault Code: Causes, Fixes & Repair Costs

What does the Biasi E19 fault code mean?

The E19 code appears on newer-generation Biasi boilers, including the Rinnova and Rinnova Adaptive ranges. It signals an 'Auxiliary Input Probe Anomaly' — meaning the boiler's control board has detected a problem with an additional temperature sensor (an NTC probe) connected to its auxiliary input. This probe feeds supplementary temperature data to the PCB; when the signal falls outside expected parameters, is absent, or is erratic, the boiler registers E19 and locks out as a safety measure. On the Rinnova Adaptive display this code appears as E19 + A. Note that older Biasi models (Riva Plus, Garda) use ER-prefixed fault codes rather than E-codes — if your boiler shows an ER code, this page does not apply.

Lockout — engineer likely May need a Gas Safe engineer 2 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Reset the boiler once or twice DIY safe

    Locate the reset button on the boiler's front panel, press and hold it for around 5–10 seconds until the display changes and the boiler attempts to restart. Allow up to 10 minutes for the ignition sequence to complete. If the boiler fires up and runs normally, monitor it over the next few hours. Do not attempt more than two or three resets in a row — if E19 returns each time, the underlying fault is still present and repeated resets will not fix it.

  2. Check whether any external controls were recently changed DIY safe

    If a smart thermostat or other external control device was installed shortly before the fault appeared, this is worth noting before you call an engineer. You do not need to re-wire anything yourself — simply let the engineer know, as incorrect wiring to the auxiliary input is a straightforward thing for them to diagnose.

  3. Contact a Gas Safe registered engineer for diagnosis Gas Safe engineer

    Because E19 points to an internal sensor, wiring, or PCB fault, professional diagnosis is required. An engineer will use a multimeter to check the resistance of the auxiliary NTC probe against its expected values at a given temperature, inspect the wiring loom and connectors for corrosion or damage, and test the PCB input circuit if the probe and wiring are found to be good. Do not attempt to test or disconnect probe wiring yourself — this involves live electrical components inside a gas appliance.

  4. Replace the faulty component as identified by the engineer Gas Safe engineer

    In most cases the engineer will replace the auxiliary NTC probe, which is typically a straightforward part swap. If the wiring is at fault, terminals and cables will be repaired or replaced. Where the PCB is implicated, the engineer will advise on the cost of replacement versus the age and condition of the boiler — a PCB replacement on an older boiler can sometimes tip the balance towards a new boiler installation.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £140–£320, depending on the underlying cause.

Frequently asked questions

Can I fix the Biasi E19 fault myself?

The initial reset is something any homeowner can safely do, but beyond that, E19 requires a Gas Safe registered engineer. The fault involves internal electrical components — specifically a temperature probe and its wiring — inside a gas appliance, and working on these without the correct qualifications is both illegal and potentially dangerous. A qualified engineer should carry out all testing and parts replacement.

How much does it cost to repair a Biasi E19 fault in the UK?

For the most common fix — replacing the auxiliary NTC probe — you can expect to pay roughly £140–£250 including parts and labour. If additional wiring work is needed, costs may rise to around £300–£320. If the PCB turns out to be the root cause, a board replacement can cost significantly more, often £350–£500 or above. As a general rule, if a repair quote is approaching £500 or more and the boiler is outside its warranty period, it is worth getting quotes for a new boiler installation to compare.

Is the Biasi E19 fault covered by warranty?

Biasi boilers come with a manufacturer's warranty of five to seven years depending on the model. If your boiler is within its warranty period, contact Biasi directly before arranging an independent engineer, as the repair or part replacement may be covered at no cost to you. Have your boiler's model number, serial number, and installation date to hand when you call.

How can I prevent the E19 fault from coming back?

Annual servicing by a Gas Safe engineer is the most effective way to catch probe and wiring deterioration before it causes a lockout. Keeping the system water clean (a magnetic filter helps trap sludge that can cause component stress), maintaining boiler pressure between 1 and 1.5 bar when cold, and ensuring any external controls are fitted by a qualified installer will all reduce the likelihood of sensor and electrical faults recurring.

Affected models: Biasi Rinnova, Biasi Rinnova Adaptive

Last reviewed 8 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Biasi E19 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →