BBiasi logo

Biasi E25 Fault Code: Causes, Fixes & Repair Costs

What does the Biasi E25 fault code mean?

The E25 code appears on Biasi boilers — including the Binova and Rinnova ranges — when the boiler detects an insufficient or inconsistent gas supply during normal operation. The boiler locks itself out as a safety precaution. Biasi's own guidance points to three areas to verify: that the gas connection is correct, that the flue outlet is clear and open, and that the gas pressure gauge (manometer) is functioning properly. Until the underlying cause is identified and resolved, the boiler will refuse to fire.

Lockout — engineer likely May need a Gas Safe engineer 4 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Check other gas appliances in the home DIY safe

    Before doing anything to the boiler, try your gas hob or another gas appliance. If nothing gas-powered is working, the problem is almost certainly with your wider gas supply. Contact your gas supplier or call the National Gas Emergency line on 0800 111 999.

  2. Reset the boiler once or twice DIY safe

    Turn the boiler off at the mains, wait at least 10 seconds, then switch it back on. Use the reset button as described in your model's manual. A single reset is worth attempting in case the lockout was caused by a one-off interruption. If E25 returns promptly after resetting, do not keep repeating it — the underlying fault needs proper diagnosis.

  3. Check the external flue terminal for obvious blockages DIY safe

    Go outside and visually inspect the flue outlet on the exterior wall or roof. Look for bird nests, leaves, or debris blocking the terminal. Do not attempt to dismantle or modify the flue yourself — if you spot a blockage you cannot safely clear from the outside, report it to your engineer.

  4. Do not attempt to adjust or replace the gas valve Gas Safe engineer

    The gas valve is a safety-critical component. Any adjustment, cleaning, or replacement must be carried out by a Gas Safe registered engineer. Working on gas components without registration is illegal and extremely dangerous.

  5. Do not attempt to inspect or replace the PCB or internal wiring Gas Safe engineer

    Internal wiring and circuit board faults require specialist diagnostic equipment and carry a serious risk of electric shock or gas-related hazard. Leave all internal electrical work to a qualified professional.

  6. Call a Gas Safe registered engineer to diagnose and repair Gas Safe engineer

    If the fault persists after one or two resets, book a Gas Safe registered engineer. They will measure incoming gas pressure with calibrated equipment, test the gas valve, inspect the flue internally, check the manometer, and assess the PCB and wiring. Always ask to see an engineer's Gas Safe ID card before allowing any work to begin.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £150–£320, depending on the underlying cause.

Frequently asked questions

Can I fix the Biasi E25 fault myself?

The only safe DIY steps are checking other gas appliances to rule out a wider supply issue, inspecting the external flue terminal for obvious debris, and resetting the boiler once or twice. Any work involving the gas valve, internal wiring, PCB, or gas pressure testing must be done by a Gas Safe registered engineer. Working on gas components without registration is illegal in the UK.

How much does it cost to fix a Biasi E25 fault?

Most people with this fault pay somewhere between £150 and £320 all-in, depending on what the engineer finds. A gas valve replacement with labour typically falls in the £150–£220 range. A flue inspection and clearance is usually £80–£150. If the fault turns out to be a failed PCB, parts alone can cost £150–£300 or more, pushing the total higher — in that scenario it is worth weighing up the repair cost against a replacement boiler, particularly if the unit is outside its warranty period.

Why does E25 keep coming back after I reset it?

A reset clears the lockout but does nothing to address the underlying cause. If E25 returns after each reset, something is genuinely wrong — most likely a gas valve that is beginning to fail, an intermittent gas pressure problem, or a sensor or PCB issue. Repeatedly resetting without repair can mask the problem and delay a fix. Book an engineer if the code reappears more than once.

Is my Biasi boiler still under warranty?

Biasi typically offers warranties of five to seven years depending on the model. If your boiler is still within this period, contact Biasi directly before paying for independent repairs — a warranty claim could cover parts and labour at no cost to you. Keep your installation paperwork and any service records to hand when you call.

Affected models: Biasi Binova, Biasi Rinnova, Biasi M90E, Biasi M96E

Last reviewed 8 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Biasi E25 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →