Biasi E24 Fault Code: Causes, Fixes & Repair Costs

What does the Biasi E24 fault code mean?

The E24 code on a Biasi boiler has two distinct meanings depending on which model range you own. On newer Biasi models (such as the Rinnova), E24 signals a probable flue or chimney obstruction — the control board has detected that combustion gases are not being safely expelled and has locked the boiler out as a precaution. On older Biasi models (such as the Riva and 24S ranges), E24 indicates incorrect burner operation during ignition — the burner failed to establish properly when the boiler attempted to fire. In both cases the boiler will not operate until the underlying fault is resolved. Check your model handbook if you are unsure which definition applies; the troubleshooting approach overlaps significantly either way.

Lockout — engineer likely May need a Gas Safe engineer 7 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Reset the boiler once or twice DIY safe

    Locate the reset button on the boiler's front panel and hold it for approximately 5–10 seconds until the display changes or the boiler restarts. Allow up to 10 minutes for the full ignition sequence to complete. Do not attempt more than two resets in succession — repeated failed ignition attempts can allow gas to accumulate in the combustion chamber, which is dangerous.

  2. Inspect the external flue terminal for obstructions DIY safe

    Go outside and visually inspect the flue outlet on the external wall. Look for bird nests, leaves, debris, or any physical blockage around the terminal. If you can safely reach it at ground level or from a safe step, gently clear away any loose material. Do not use ladders in unsafe conditions and do not attempt to dismantle or modify the flue.

  3. Confirm the gas supply is turned on DIY safe

    Check that the gas isolation valve on the pipe leading to the boiler is in the open (inline) position. Also check that other gas appliances in the property — such as a hob or gas fire — are working normally. If no gas appliances are working, there may be a supply interruption; contact your gas supplier.

  4. Check the electricity supply and connections DIY safe

    Ensure the boiler is properly plugged in or that its fused spur switch is turned on. A loose plug connection can occasionally cause control board errors. Do not open the boiler casing or interfere with any internal wiring.

  5. Call a Gas Safe registered engineer to diagnose and repair Gas Safe engineer

    If the fault code returns after one or two resets, or if none of the above checks resolve the issue, a Gas Safe registered engineer must be called. They will test the fan output, inspect the air pressure switch with appropriate instruments, check the flue system internally, assess the ignition electrodes and ionisation sensor, and test gas pressure at the boiler. Any replacement of the fan, APS, gas valve, PCB, or burner components must be carried out by a registered professional.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £120–£380, depending on the underlying cause.

Frequently asked questions

My Biasi boiler shows E24 — which meaning applies to my model?

The easiest way to tell is to check your boiler's model name, which is usually printed on a label inside the front panel or in the manual. If you have a Rinnova, the E24 code specifically relates to a flue or ventilation fault. If you have an older model such as a Riva, Riva Plus, Garda, or 24S, E24 points to a burner ignition failure. Both faults share some common causes — such as a faulty fan — so a Gas Safe engineer's diagnostic approach will cover both possibilities regardless.

Can I fix Biasi E24 myself, or do I always need an engineer?

There are a handful of checks you can safely carry out yourself: resetting the boiler (once or twice only), inspecting the external flue terminal for obvious blockages like leaves or a bird's nest, confirming your gas supply is on, and checking the boiler's plug or fused spur. Beyond these steps, the fault requires internal investigation — testing the fan, air pressure switch, ignition components, or gas valve — all of which must be done by a Gas Safe registered engineer. Attempting internal gas boiler repairs yourself is both illegal and potentially life-threatening.

How much does it typically cost to fix a Biasi E24 fault?

Most people with this fault pay somewhere between £120 and £380 once labour and parts are included. A straightforward fix such as cleaning ignition components or replacing an air pressure switch tends to sit at the lower end of that range. Replacing the fan usually brings the cost towards the upper end. In rare cases where the PCB needs replacing the bill can climb to £400–£500 or more, and on older Biasi boilers it is worth getting a new boiler quote alongside any repair quote above roughly £500, as replacement may be more economical in the long run.

Why does my Biasi keep coming back with E24 after I reset it?

A single reset clearing the fault temporarily usually means the fault condition is intermittent — perhaps a fan that is starting to fail, a partially blocked flue, or a gas supply that dips occasionally. If the code returns reliably within a short period of each reset, the underlying component has most likely failed and needs replacing. Repeated resets without diagnosis are not a solution and can mask a worsening fault; arrange for a Gas Safe engineer to investigate before the boiler fails completely, especially heading into colder weather.

Affected models: Biasi Rinnova, Biasi Riva, Biasi 24S, Biasi Riva Plus, Biasi Garda, Biasi Inovia, Biasi Advance Plus

Last reviewed 8 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Biasi E24 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →