Daikin A5-00 Fault Code: Causes, Fixes & Repair Costs

What does the Daikin A5-00 fault code mean?

The A5-00 fault code indicates that the indoor heat exchanger has exceeded its safe operating limits — either overheating during a heating cycle (high-pressure protection) or entering freeze-up protection during a cooling cycle. The '-00' sub-code denotes the primary detection event. When the system's control board detects that refrigerant pressures or heat exchanger temperatures have moved outside their acceptable range, it locks out operation and displays this code to prevent component damage.

Lockout — engineer likely 7 models affected

General guidance only — not a substitute for professional advice, and not certified by an heat pump engineer. Always have your specific appliance assessed by a qualified professional. Any heat pump work must be carried out by an MCS-certified heat pump engineer. If you notice a refrigerant leak, a burning smell or water leaking from the unit, switch it off at the isolator and call an MCS-certified heat pump engineer. Refrigerant work must be carried out by an F-Gas registered engineer.

Common causes

How to fix it

  1. Switch the unit off at the controller and allow at least 30 minutes for any ice on the indoor coil to thaw DIY safe

    Do not attempt to defrost the coil manually with any heat source. Simply let the system sit unpowered. If you can see visible ice or heavy condensation around the indoor unit, this confirms freeze-up was involved. Place some towels below the unit to catch melt water.

  2. Check and clean the indoor air filter DIY safe

    Open the indoor unit's front panel and carefully remove the filter cartridge. If it is visibly grey with dust, rinse it under lukewarm water, allow it to dry completely (do not refit a wet filter), then reinstall it. This single step resolves a significant proportion of A5-00 callouts and costs nothing.

  3. Clear any obstructions around the outdoor unit DIY safe

    Walk around the outdoor unit and remove any accumulated leaves, garden debris, or snow that is blocking the intake or discharge grille. Maintain at least the clearance specified in your installation manual — typically 300 mm on the intake side and 500 mm from the fan discharge. Do not reach into the fan aperture.

  4. Check the system pressure on the filling loop or pressure gauge DIY safe

    Low water-side pressure in the heating circuit (below approximately 1.0 bar on most Daikin Altherma systems) can indirectly stress the heat exchanger. Check the pressure gauge on the unit or the buffer cylinder. If it reads below the manufacturer's recommended range (typically 1.0–2.0 bar), top up via the filling loop following your system's user guide. If the system keeps losing pressure, inform the engineer — there may be a leak on the water side.

  5. Reset the unit from the controller and observe whether A5-00 returns DIY safe

    Once the filter is clean, ice has thawed, and the outdoor unit is clear, restore power and attempt a reset from the Daikin controller or BRC user interface (hold the reset function as described in your user manual). Run the system for 20–30 minutes and monitor whether the fault code reappears. A fault that clears and stays clear suggests the filter was the culprit. A fault that returns promptly indicates a deeper issue requiring professional attention.

  6. If the fault persists, arrange an inspection by an MCS-certified heat pump engineer heat pump engineer

    A returning A5-00 points to one of the refrigerant-circuit or sensor faults that a homeowner cannot safely diagnose or repair. The engineer will check refrigerant pressures, test the heat exchanger thermistor, inspect the expansion valve and its coil, and verify PCB connections. Any refrigerant leak detection, recovery, or recharge must be carried out by an F-Gas registered engineer under UK regulations. Do not attempt to access the sealed refrigerant circuit yourself.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £120–£420, depending on the underlying cause.

Frequently asked questions

Can I fix Daikin A5-00 myself without calling an engineer?

The only homeowner-safe steps are cleaning the air filter, clearing snow or debris from around the outdoor unit, checking that the system pressure is within range, and performing a reset. These actions resolve A5-00 in a meaningful number of cases — particularly if the filter has not been cleaned in several months. However, if the fault returns after those checks, the underlying cause almost certainly involves the refrigerant circuit, expansion valve, or a sensor, all of which require a qualified professional. Attempting to access the sealed refrigerant circuit yourself is unsafe, illegal without F-Gas registration, and will void your warranty.

How much does it typically cost to fix a Daikin A5-00 fault in the UK?

Most households with this fault pay somewhere between £120 and £420 all-in, covering a diagnostic visit plus the most common repairs such as a professional coil clean, a thermistor replacement, or an EV coil swap. Refrigerant leak repairs add cost — expect £150–£350 on top depending on the extent of the leak and the refrigerant type. At the more expensive end, a faulty expansion valve assembly or PCB can push costs higher; a compressor replacement (rare for this fault code) can reach £1,500 or more, but that is genuinely unusual for an A5-00 presentation. If your unit is still under warranty or you hold a Daikin maintenance contract, parts and labour costs may be covered in full.

Why does my Daikin keep showing A5-00 after I reset it?

A fault code that clears on reset but comes back within a few hours or days has not been fixed — the reset simply clears the log entry while the underlying problem continues. Recurring A5-00 typically means restricted airflow that persists (either a deeply fouled coil that needs a chemical wash, not just a filter rinse), a refrigerant circuit that is slowly losing charge through a leak, or a failing thermistor giving erratic readings. Each time the system hits the protective threshold, it will lock out again. An MCS-certified engineer with manifold gauges and diagnostic equipment is needed to find the root cause.

How often should I service my Daikin heat pump to avoid A5-00?

Daikin recommends inspecting and cleaning the indoor air filter every two months during regular use — this is a straightforward homeowner task. A full annual service by an MCS-certified engineer should also be scheduled, during which the refrigerant pressures, expansion valve operation, coil cleanliness, thermistor readings, and water-side pressure are all verified. Skipping annual servicing is a leading contributor to A5-00 faults and can also invalidate your warranty or MCS certification records, which matters if you receive the Boiler Upgrade Scheme (BUS) grant.

Affected models: Daikin Altherma 3 R, Daikin Altherma 3 H, Daikin Altherma HT, Daikin Altherma M, Daikin EDLQ Series, Daikin EHBH/EHVH Series, Daikin multi-split indoor units (compatible outdoor units displaying A5-00)

Last reviewed 1 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a heat pump engineer

✓ Your boiler details: Daikin A5-00 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →