Daikin L5-00 Fault Code: Causes, Fixes & Repair Costs

What does the Daikin L5-00 fault code mean?

The L5-00 code is triggered when the outdoor unit's inverter board detects an instantaneous current spike on its output to the compressor — one that exceeds the built-in protection threshold, even if only for a fraction of a second. The moment this happens, the board cuts power to the compressor and locks the system out completely. Unlike a gradual overcurrent event, L5 points to a hard electrical fault: the inverter is essentially detecting that something is drawing far more current than it should, right from the moment it tries to start the compressor. The indoor controller will display L5-00 and the unit will not respond to the remote or restart itself. You may hear the outdoor fan spin up briefly, followed by a thump or hum from the compressor, and then silence — that sound is the compressor attempting and failing to start.

Lockout — engineer likely 6 models affected

General guidance only — not a substitute for professional advice, and not certified by an heat pump engineer. Always have your specific appliance assessed by a qualified professional. Any heat pump work must be carried out by an MCS-certified heat pump engineer. If you notice a refrigerant leak, a burning smell or water leaking from the unit, switch it off at the isolator and call an MCS-certified heat pump engineer. Refrigerant work must be carried out by an F-Gas registered engineer.

Common causes

How to fix it

  1. Do not repeatedly attempt to restart the unit DIY safe

    Each restart attempt when a hard electrical fault is present risks causing further damage to the inverter PCB. Limit yourself to a single reset attempt as described below. If L5-00 returns immediately or within minutes, stop and arrange an engineer visit.

  2. Check that the outdoor unit service valves are fully open DIY safe

    On the outdoor unit, locate the refrigerant pipe connections. Each pipe has a cap covering an Allen-key valve. If the unit has been recently installed or serviced, check that these valves are in the fully open position (Allen key turned fully anti-clockwise). If you are unsure or cannot safely access them, leave this to an engineer.

  3. Check for obvious obstructions around the outdoor unit DIY safe

    Walk around the outdoor unit and look for anything that could be blocking airflow — compacted snow, fallen leaves, garden debris, or items stored too close. Clear any obstructions and ensure there is at least 30 cm of clear space around all sides of the unit.

  4. Check your consumer unit for a tripped MCB DIY safe

    Go to your consumer unit (fuse board) and check whether the MCB or RCD protecting the heat pump circuit has tripped. If it has, reset it once. If it trips again immediately, do not attempt a further reset — contact an engineer, as repeated tripping indicates a persistent electrical fault.

  5. Perform a single power reset DIY safe

    Switch off the heat pump at its dedicated isolator (usually a red or grey switch near the outdoor unit or in the plant room). Wait a full two minutes to allow the inverter's DC bus capacitors to discharge safely, then switch the isolator back on. Attempt to restart the unit from the controller. If L5-00 returns, do not reset again.

  6. Arrange for an F-Gas registered, MCS-certified heat pump engineer to carry out a full diagnosis heat pump engineer

    If the fault persists after a single reset, professional diagnosis is required. An engineer will disconnect the compressor and resistance-test the U, V, and W windings, perform insulation testing with a megohmmeter, inspect the IPM and inverter PCB for damage, check the U-V-W wiring harness for shorts, and test inverter output waveform balance. This work involves potentially lethal DC voltages and specialist test equipment — it must not be attempted by anyone other than a qualified engineer.

  7. Allow the engineer to replace the faulty component heat pump engineer

    Depending on diagnosis, the repair will typically be either an inverter PCB/IPM replacement or a compressor replacement. Compressor replacement involves recovering the existing refrigerant charge (F-Gas registered engineer required), replacing the compressor and filter-drier, evacuating the circuit, and recharging with a measured refrigerant quantity. Neither repair is suitable for DIY.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £450–£950, depending on the underlying cause.

Frequently asked questions

Is it safe to keep resetting the unit when L5-00 appears?

No. A single reset is reasonable to rule out a transient fault, but if L5-00 returns, further resets risk damaging the inverter PCB. Each time the inverter tries to start a compressor with shorted windings or a seized motor, it puts the power module under extreme stress. Stop resetting and book an engineer.

Does L5-00 always mean I need a new compressor?

Not necessarily. While a failing compressor is a common cause, L5-00 can also result from a faulty inverter PCB or IPM module, a wiring short, or even closed service valves on a recently serviced unit. An engineer needs to carry out winding resistance tests and PCB diagnostics to confirm which component has failed before any parts are ordered. Inverter PCB replacement is significantly cheaper than a compressor swap.

How much does it typically cost to fix L5-00 on a Daikin heat pump in the UK?

For most people, the repair will be either an inverter PCB replacement — typically £450–£950 including parts and labour — or a compressor replacement, which usually falls in the range of £1,500–£2,000 when you factor in parts, labour, refrigerant recovery and recharge, and a new filter-drier. On units that are eight years old or more, some engineers and homeowners decide that a full system replacement represents better long-term value than a costly compressor repair, particularly if the unit is out of warranty.

My Daikin heat pump is still under warranty — what should I do?

Contact Daikin UK or your installing MCS-certified engineer before arranging any third-party repair. Daikin typically logs the fault and arranges for an approved service partner to attend. Having the unit worked on without authorisation during the warranty period could result in the warranty being voided and any visit being chargeable. Daikin heat pumps generally carry a 5–7 year warranty, with extensions of up to 12 years available when the product is registered and serviced annually by an approved engineer.

Why does L5-00 cause a complete lockout rather than just a temporary shutdown?

L5-00 is a hard protection event, not a recoverable alarm. The inverter board is designed to cut output instantly and latch the fault because the underlying cause — a current spike of this magnitude — indicates a serious electrical problem. Allowing the system to keep attempting to restart could cause irreparable damage to the inverter's power module or create a safety hazard. The lockout forces the fault to be properly investigated before the system runs again.

Affected models: Daikin Altherma 3, Daikin Altherma R, Daikin Altherma HT, Daikin EDLQ series, Daikin EHBH/EHVH series, Daikin ERLQ series

Last reviewed 16 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a heat pump engineer

✓ Your boiler details: Daikin L5-00 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →