Daikin C4-00 Fault Code: Causes, Fixes & Repair Costs

What does the Daikin C4-00 fault code mean?

The C4-00 fault code indicates that the indoor heat exchanger thermistor — the sensor responsible for monitoring the temperature of the indoor coil — is returning abnormal readings. The control board interprets this as either an open circuit (sensor disconnected or broken) or a short circuit (sensor or wiring shorted to earth). Because the heat pump relies on this reading to manage refrigerant superheat and subcooling safely, it enters a protective lockout rather than risk damage to the compressor or refrigerant circuit.

Lockout — engineer likely 6 models affected

General guidance only — not a substitute for professional advice, and not certified by an heat pump engineer. Always have your specific appliance assessed by a qualified professional. Any heat pump work must be carried out by an MCS-certified heat pump engineer. If you notice a refrigerant leak, a burning smell or water leaking from the unit, switch it off at the isolator and call an MCS-certified heat pump engineer. Refrigerant work must be carried out by an F-Gas registered engineer.

Common causes

How to fix it

  1. Check for any obvious causes near the outdoor unit DIY safe

    Before calling an engineer, do a quick external check. Clear any debris, leaves or compacted snow from around the outdoor unit that might be causing airflow problems contributing to abnormal sensor readings. Ensure the unit has not been physically disturbed.

  2. Inspect the system pressure DIY safe

    Check the pressure gauge on the indoor unit or buffer vessel. Most Daikin heat pump systems should read between 1.0 and 2.0 bar when cold. If pressure is low, top up via the filling loop according to your system manual. Low pressure alone will not cause C4-00, but it confirms the system is being maintained and rules out compounding issues.

  3. Perform a hard power reset DIY safe

    Turn the heat pump off at the controller, then switch off the dedicated circuit breaker (MCB) in the consumer unit. Leave the system fully de-energised for at least three minutes. Restore power and allow the unit to restart normally. A genuine temporary glitch can occasionally be cleared this way. If C4-00 reappears within a short time, the fault is real and requires a professional visit.

  4. Record the full fault code and any accompanying codes DIY safe

    On most Daikin controllers, pressing and holding the 'Cancel' or 'Mode' button for around five seconds will display the stored fault history. Note down C4-00 and any secondary codes shown — this information will help the attending engineer diagnose the fault more quickly and may save you diagnostic time costs.

  5. Arrange an MCS-certified Daikin-approved engineer to inspect the thermistor and wiring heat pump engineer

    The engineer will access the indoor unit, unplug the thermistor connector and test the sensor's resistance against the manufacturer's temperature-resistance curve. They will also check the wiring harness for continuity and inspect the connector for corrosion or damage. This is not a task for an unqualified person — incorrect handling of internal electrical components can cause further damage and void the warranty.

  6. Replace the thermistor with a genuine Daikin part if the sensor is confirmed faulty heat pump engineer

    Daikin thermistors have a specific resistance curve; fitting a generic replacement with a slightly different curve can cause the unit to operate outside safe parameters, leading to poor performance or repeat faults. The engineer will seat the new sensor fully into its copper pocket and use thermal compound to ensure accurate thermal contact.

  7. Investigate refrigerant charge if the fault persists after sensor replacement heat pump engineer

    If C4-00 returns or coil temperatures remain erratic after a confirmed good sensor is fitted, the refrigerant circuit should be checked for correct charge. Refrigerant work must be carried out by an F-Gas registered engineer — it is illegal for unqualified individuals to handle refrigerants in the UK.

  8. Replace the indoor PCB if all other components test satisfactorily heat pump engineer

    When the thermistor, wiring and refrigerant charge are all confirmed good but the fault persists, the indoor control board is the remaining suspect. PCB replacement should be carried out by the attending engineer using a genuine Daikin board, as incorrect fitting or an incompatible board can cause further control faults.

  9. Contact an MCS-certified heat pump engineer if the fault has not self-cleared after a reset heat pump engineer

    If the power reset in step 3 did not clear the fault, do not continue attempting workarounds. Book a visit from an MCS-certified, Daikin-approved engineer. For any work involving the refrigerant circuit, confirm the engineer also holds F-Gas registration.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £150–£380, depending on the underlying cause.

Frequently asked questions

Can I reset a Daikin C4-00 fault myself?

Yes, a power reset is worth attempting first and is safe to do yourself. Switch the unit off at the controller, turn off its dedicated MCB in the consumer unit, wait three minutes, then restore power. If C4-00 clears and does not return, the fault may have been a temporary glitch. However, if the code reappears — even after a successful reset — there is an underlying hardware problem that needs a professional diagnosis. Do not keep resetting without investigating further, as continued operation on a faulty sensor can stress the compressor.

How much does it cost to fix a Daikin C4-00 fault in the UK?

For most households, the repair falls between £150 and £380, which typically covers the engineer callout, diagnosis and thermistor or connector replacement with a genuine Daikin part. If the indoor PCB turns out to be at fault, costs usually rise to the £300–£600 range for the board plus labour. In rare cases where a refrigerant recharge is also needed, add the F-Gas engineer's time and refrigerant costs on top. Big-ticket components like a replacement compressor are very unlikely to be the cause of a C4-00 code specifically, but if a full compressor replacement were ever needed for a separate reason, that can run to £1,000–£2,000 or more.

Will my Daikin warranty cover the C4-00 fault?

If your heat pump is within its manufacturer or installer warranty period, the repair may be fully covered — contact Daikin UK or your installer in the first instance. Be aware that most Daikin warranties require evidence of annual servicing; if you cannot produce service records, Daikin may decline the claim. Daikin's own Gold maintenance package includes an annual service and breakdown cover, which can make warranty compliance easier to manage.

Do I need an F-Gas engineer to fix C4-00, or will any heat pump engineer do?

The C4-00 fault is primarily a sensor and wiring issue, so in most cases the repair does not touch the sealed refrigerant circuit. An MCS-certified heat pump engineer — ideally Daikin-approved — is the right person to call. However, if the diagnosis reveals a low refrigerant charge as a contributing factor, that portion of the work must be carried out by someone who also holds F-Gas registration, as handling refrigerants without certification is illegal in the UK. Always ask the engineer about both qualifications before booking.

Affected models: Daikin Altherma 3, Daikin Altherma R, Daikin Altherma HT, Daikin FTXM series (air-to-air with heat pump mode), Daikin EDLA series, Daikin EHBH/EHVH series

Last reviewed 16 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a heat pump engineer

✓ Your boiler details: Daikin C4-00 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →