Daikin AJ-03 Fault Code: Causes, Fixes & Repair Costs

What does the Daikin AJ-03 fault code mean?

The AJ-03 warning appears on Daikin Altherma heat pumps when the domestic hot water (DHW) cylinder has taken longer than 6 hours to reach its target temperature. Unlike a hard lockout fault, the system keeps running — but the warning flags that something is preventing the hot water from heating up within a normal timeframe. This could be a settings issue, a component fault, or simply unusually high hot water demand in the household.

Engineer may be needed Some DIY checks possible 4 models affected

General guidance only — not a substitute for professional advice, and not certified by an heat pump engineer. Always have your specific appliance assessed by a qualified professional. Any heat pump work must be carried out by an MCS-certified heat pump engineer. If you notice a refrigerant leak, a burning smell or water leaking from the unit, switch it off at the isolator and call an MCS-certified heat pump engineer. Refrigerant work must be carried out by an F-Gas registered engineer.

Common causes

How to fix it

  1. Check the outdoor unit and surrounding area DIY safe

    Walk around the outdoor unit and confirm it is free from obstructions — snow, ice build-up, leaves, or debris blocking the airflow will reduce efficiency significantly. Clear anything within at least half a metre of the unit on all sides.

  2. Check the system water pressure DIY safe

    Look at the pressure gauge on the indoor unit or buffer vessel. It should read between 1.5 and 2 bar when cold. If it is sitting at or below 1 bar, the system is undercharged. Consult your installer's handover notes or the unit manual for how to top up pressure using the filling loop — this is a homeowner-safe task on most installations.

  3. Review your DHW schedule on both the MMI and the Daikin app DIY safe

    Open the on-unit controller (MMI) and the Daikin app and compare the DHW heating schedules. Make sure the hot water heating window is long enough — typically at least 2–3 hours for a standard cylinder, longer in winter. Ensure the backup or booster heater is enabled in the settings if your system has one. Correct any discrepancies between the app and the MMI, as conflicting settings are a surprisingly common trigger.

  4. Consider recent hot water usage DIY safe

    If several people have used hot water in quick succession, or an unusually large draw-off occurred (e.g. filling a bath), the warning may simply be a one-off event. Monitor whether it clears once the cylinder recovers and assess whether your cylinder size and settings are appropriate for your household's demand.

  5. Reset the unit at the isolator DIY safe

    Turn the heat pump off at the red isolation switch (usually on the wall near the outdoor unit or indoor unit). Wait at least 5 minutes, then switch it back on and allow the system to restart. Monitor whether the fault returns. A one-off warning that does not reappear after a reset and a review of your schedule is unlikely to need an engineer visit.

  6. Check for dripping taps or leaks on the hot water pipework DIY safe

    Check all hot water taps and any visible DHW pipework for drips or continuous flow. Even a slow drip can introduce enough cold water to prevent the cylinder from holding temperature. Fix any dripping taps or ask a plumber to do so.

  7. Have an MCS-certified engineer inspect the 3-way valve, heater elements, thermistor and PCBs heat pump engineer

    If the warning persists after the homeowner checks above, the fault is likely inside the unit. A qualified heat pump engineer will need to test the 3-way valve operation, check the DHW thermistor (R5T) for accuracy, inspect the backup and booster heater elements and their fuses, and examine the hydro PCBs. None of these tasks are safe or appropriate for a homeowner to attempt. If your unit is still under warranty, contact Daikin before booking an independent engineer to ensure the visit is authorised and covered.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £150–£500, depending on the underlying cause.

Frequently asked questions

Is the AJ-03 fault serious — will my heat pump shut down?

No, AJ-03 is a warning rather than a lockout. Your Daikin Altherma will continue operating, but it is flagging that the hot water cylinder is taking too long to reach its target temperature. You should investigate the cause, but you are unlikely to be left with no heating or hot water immediately. That said, if the underlying cause is a faulty component such as the 3-way valve or a heater element, the problem will not fix itself and should be addressed promptly.

Can I fix AJ-03 myself, or do I need an engineer?

Several of the most common triggers — a too-short DHW schedule, a settings mismatch between the app and the MMI, low system pressure, or a temporary spike in hot water demand — are things a homeowner can check and correct without any specialist knowledge. Start by reviewing your schedule settings, checking system pressure, and doing a reset at the isolator. If the fault keeps coming back after those checks, you will need an MCS-certified heat pump engineer to investigate internal components such as the 3-way valve, heater elements, and thermistor.

How much will it cost to fix AJ-03 on my Daikin Altherma?

If the fix is a settings adjustment or a system reset, the only cost is an engineer call-out if you need one — typically £150–£300 depending on whether you use a Daikin-direct service or an independent MCS-certified engineer. For a component repair, a thermistor replacement typically comes to around £150–£250 all in, while a 3-way valve or heater element replacement usually falls in the £250–£500 range including labour. PCB replacements can cost more and are worth discussing with your engineer before authorising. If your unit is within its warranty period, contact Daikin before booking any work.

Why does AJ-03 keep coming back even after a reset?

A recurring AJ-03 warning after a reset almost always points to a component fault or a persistent settings problem rather than a one-off event. The most common culprits are a partially stuck 3-way valve that is not fully diverting flow to the cylinder, a backup or booster heater that has failed or been accidentally disabled, or a DHW schedule that is genuinely too short for your household's hot water demand. A misreading thermistor is another possibility. If you have already reviewed your schedule and confirmed settings are correct, book an MCS-certified engineer to carry out a thorough inspection.

Affected models: Daikin Altherma 3 R F, Daikin Altherma 3 H, Daikin Altherma Low Temperature Split, Daikin Altherma Monobloc

Last reviewed 16 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a heat pump engineer

✓ Your boiler details: Daikin AJ-03 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →