Daikin L3-00 Fault Code: Causes, Fixes & Repair Costs

What does the Daikin L3-00 fault code mean?

The L3-00 fault code signals that the outdoor unit's electrical compartment has reached a dangerously high temperature — specifically above 120°C — while the compressor is not running. The unit has shut itself down as a protective measure. In plain terms, the electronics housed inside the outdoor unit are overheating, and the system will not resume normal operation until the underlying cause is identified and resolved. This should be treated as urgent: if the inverter cooling fan has stopped working, the PCB can be the next component to fail, turning a relatively straightforward repair into a much costlier one.

Stop & check now 6 models affected

General guidance only — not a substitute for professional advice, and not certified by an heat pump engineer. Always have your specific appliance assessed by a qualified professional. Any heat pump work must be carried out by an MCS-certified heat pump engineer. If you notice a refrigerant leak, a burning smell or water leaking from the unit, switch it off at the isolator and call an MCS-certified heat pump engineer. Refrigerant work must be carried out by an F-Gas registered engineer.

Common causes

How to fix it

  1. Switch the unit off at the controller and then at the outdoor isolator DIY safe

    Do not attempt to run the unit through this fault. L-series codes in Daikin's system indicate active overheating protection — continuing to operate the unit risks cascading damage to the inverter board and potentially the compressor. Turn the unit off at the wall controller first, then switch the outdoor isolator to the off position.

  2. Check for obvious blockages around the outdoor unit DIY safe

    Walk around the outdoor unit and look at the louvres and grilles. Remove any leaves, dirt, cobwebs, or debris that may be restricting airflow. Ensure there is at least 30 cm of clear space on all sides of the unit. If the unit is hemmed in by fencing, planting, or a cover box, this may be a contributing factor worth addressing before calling an engineer.

  3. Wait at least five minutes before attempting a reset DIY safe

    The inverter capacitors inside the outdoor unit take several minutes to discharge after power is removed. Switching the isolator back on immediately can stress the electronics. Wait a full five minutes with the isolator off, then restore power, allow two minutes for the system to initialise, and observe whether the unit starts normally or immediately returns the L3-00 code.

  4. Attempt a single power reset and monitor closely DIY safe

    If the unit restarts without immediately showing the fault, monitor it closely for the first hour of operation. Listen for the outdoor fan spinning freely and check that warm air is being expelled from the unit. If L3-00 returns within an hour, you have a confirmed fault rather than a one-off glitch. Do not reset more than twice — repeated resets through an active fault can layer additional damage onto already stressed components.

  5. Book an MCS-certified heat pump engineer to diagnose and repair the fault heat pump engineer

    An engineer will use Daikin-compatible diagnostic equipment to confirm which component has triggered the thermal protection. They will test the outdoor fan motor and the inverter cooling fan, inspect and measure the power transistor, check the inverter PCB for heat damage, reapply thermal paste to inverter components if it has degraded, and replace whichever component has failed. Any work involving the inverter, compressor, or refrigerant circuit must be carried out by an F-Gas registered engineer.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £180–£550, depending on the underlying cause.

Frequently asked questions

Is it safe to keep using my heat pump when L3-00 is showing?

No — the unit has shut itself down for a reason. The electrical compartment has exceeded its safe operating temperature and running the system through this fault risks permanent damage to the inverter board and, in the worst case, the compressor. Switch the unit off and arrange an engineer visit promptly. A fan motor replacement costing a few hundred pounds can quickly become a compressor replacement costing well over a thousand if the overheating is allowed to continue.

Can I fix a Daikin L3-00 fault myself?

A homeowner can safely clear debris from around the outdoor unit and attempt a single controlled power reset. Beyond that, the fault requires a qualified engineer. The inverter, fan motor, power transistor, and PCB are all inside the outdoor unit's electrical compartment and must not be accessed by anyone who is not trained and certified. Any work on the refrigerant or sealed circuit also requires an F-Gas registered engineer by law.

How much does it cost to repair a Daikin L3-00 fault in the UK?

For most people, the repair comes down to either a fan motor replacement or an inverter board replacement. Fan motor and minor component repairs typically cost £180–£350 including parts and labour. If the overheating has damaged the inverter PCB, expect £450–£900. In cases where the fault was left undetected for a long time and secondary damage has spread to the compressor, costs can exceed £1,400 — which is why early diagnosis matters. Always ask your engineer for a written quote before authorising any work.

Will my Daikin warranty cover an L3-00 fault?

Daikin's standard residential warranty covers manufacturing defects for three years from installation, provided the unit has been serviced annually by an F-Gas certified engineer and service records have been kept. If the overheating was caused by a manufacturing defect in the fan motor or PCB, a warranty claim may be valid. However, faults caused by restricted airflow, lack of maintenance, or wear and tear are typically not covered. Contact your installing engineer or Daikin UK directly with your installation date and service history before paying for parts.

Affected models: Daikin Altherma 3, Daikin Altherma R32, Daikin Altherma LT, Daikin Altherma HT, Daikin split-type heat pumps (various outdoor units), Daikin multi-split heat pump systems

Last reviewed 16 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a heat pump engineer

✓ Your boiler details: Daikin L3-00 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →