Daikin H9-00 Fault Code: Causes, Fixes & Repair Costs

What does the Daikin H9-00 fault code mean?

The H9-00 fault code points to a problem with the outdoor air temperature sensor — known internally as the R1T thermistor — fitted inside the outdoor unit. This sensor continuously monitors the ambient air temperature outside, and the heat pump's control board uses that reading to manage defrost cycles, capacity output and general operation. When the resistance value returned by the sensor falls outside the expected range, the control board flags it as H9-00 and will typically shut the unit down to protect the system from running with inaccurate temperature data. The -00 sub-code indicates this is the standard presentation of the fault with no additional qualifier.

Lockout — engineer likely 6 models affected

General guidance only — not a substitute for professional advice, and not certified by an heat pump engineer. Always have your specific appliance assessed by a qualified professional. Any heat pump work must be carried out by an MCS-certified heat pump engineer. If you notice a refrigerant leak, a burning smell or water leaking from the unit, switch it off at the isolator and call an MCS-certified heat pump engineer. Refrigerant work must be carried out by an F-Gas registered engineer.

Common causes

How to fix it

  1. Switch the unit off at the outdoor isolator and wait at least 30 seconds before restarting DIY safe

    A full power-down — at the wall isolator or fused spur, not just from the indoor controller — clears the fault register. Intermittent connector issues can produce a one-off H9-00 that does not return after a reset. If the code reappears within a short time of normal operation, proceed to the next steps.

  2. Clear any debris, ice or blockage from around the outdoor unit DIY safe

    Check that the outdoor unit has adequate clearance on all sides and that leaves, dirt or ice are not blocking the casing vents. While this is unlikely to directly cause H9-00, it is good practice before calling an engineer and ensures the unit is operating in its intended environment.

  3. Check the system water pressure on the indoor unit display DIY safe

    Confirm that system pressure is within the manufacturer's recommended range (typically 1.0–2.0 bar when cold). Low pressure will not cause H9-00 but may generate additional faults alongside it. Top up via the filling loop if pressure is below 1.0 bar and there are no signs of a leak.

  4. Have an MCS-certified engineer inspect and reseat the thermistor connector on the outdoor PCB heat pump engineer

    An engineer will power down the unit safely, open the outdoor unit casing and locate the R1T thermistor connector on the control board. If the connector is loose, corroded or damaged, reseating or replacing the connector plug is a quick and low-cost fix. This step alone resolves a significant proportion of H9-00 faults.

  5. Have the engineer test the R1T thermistor resistance and replace if out of specification heat pump engineer

    Using a multimeter, the engineer checks the thermistor's resistance at the measured ambient temperature against Daikin's reference values. If the reading is significantly off, the sensor is replaced with a genuine Daikin OEM part. Using non-OEM sensors risks introducing resistance variance that can cause the fault to recur.

  6. Have the engineer inspect and replace the outdoor unit PCB if the sensor tests as healthy heat pump engineer

    If both the connector and the thermistor are confirmed to be functioning correctly but H9-00 persists, the outdoor control board itself is the likely culprit. PCB replacement is a more involved and more costly repair but is the correct resolution when other causes have been eliminated.

  7. Contact an MCS-certified heat pump engineer to diagnose and repair the fault heat pump engineer

    If H9-00 returns after a reset or you have not been able to identify the cause through the safe checks above, arrange a visit from an MCS-certified engineer. Daikin warranty holders should contact a Daikin Approved Service Partner directly to ensure warranty cover is preserved and genuine parts are used.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £180–£350, depending on the underlying cause.

Frequently asked questions

Can I reset a Daikin H9-00 fault myself?

Yes — a power-down reset at the outdoor isolator is a safe first step any homeowner can take. Switch the unit off at the isolator (not just the controller), wait at least 30 seconds, then restart. If the code does not return, monitor the unit over the next day or two. If H9-00 comes back, the fault is genuine and persistent, and you should book an engineer rather than repeatedly resetting.

How much does it cost to fix a Daikin H9-00 fault in the UK?

The most common repair — reseating or replacing the outdoor air thermistor and its connector — typically costs between £180 and £350 including parts and labour. If the outdoor unit PCB turns out to be faulty, expect to pay considerably more, often £450 to £900 depending on the model and the specific board required. If your system is still under a Daikin warranty or a maintenance plan, the repair may be covered — check your agreement before booking an independent engineer.

Is the Daikin H9-00 fault dangerous?

No, H9-00 is not a safety-critical alarm in the way that a refrigerant leak or electrical fault would be. It means the heat pump cannot reliably read the outdoor air temperature and has shut down to prevent inefficient or potentially damaging operation. Your home may lose heating or hot water while the fault is active, but there is no immediate risk to people or property. You should still arrange a repair promptly to avoid extended loss of heating, particularly in cold weather.

Why does my Daikin keep showing H9-00 even after I replace the thermistor?

If H9-00 returns after a sensor replacement, the most likely explanation is either a wiring or connector issue that was not addressed at the same time, or a fault on the outdoor unit PCB itself. It is also worth ensuring that the replacement sensor was a genuine Daikin OEM part — third-party sensors can have slightly different resistance characteristics that the control board misreads as out-of-range. Ask your engineer to test the full wiring path from sensor to PCB and confirm board functionality before fitting another sensor.

Affected models: Daikin Altherma 3, Daikin Altherma R, Daikin Altherma Low Temperature Split, Daikin Altherma 3 R F, Daikin Altherma 3 H HT, Daikin Altherma Monobloc

Last reviewed 16 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a heat pump engineer

✓ Your boiler details: Daikin H9-00 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →