Glow-worm Temperature 30 Flashing Fault Code: Causes, Fixes & Repair Costs

What does the Glow-worm Temperature 30 Flashing fault code mean?

On Glow-Worm boilers, a flashing temperature reading of around 30°C is most often a completely normal display behaviour rather than a fault. It typically appears during the pump overrun phase — the short period after the burner shuts off when the circulation pump keeps running to dissipate residual heat from the heat exchanger. You may notice it more in warmer months when thermostatic radiator valves (TRVs) have closed across much of the system. However, if the flashing is persistent, the boiler is cutting out repeatedly, or your heating and hot water are not performing as expected, it can point to an underlying issue such as restricted flow, a failing NTC thermistor (temperature sensor), or a circulation problem. In those cases, the boiler may be struggling to dissipate heat properly and could be approaching its overheat limit.

Engineer may be needed Some DIY checks possible May need a Gas Safe engineer 7 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Check whether the flashing is normal pump overrun DIY safe

    Observe the boiler for a few minutes after it has reached temperature. If the display temperature flashes briefly, the burner is off, the pump is still running, and your heating and hot water are working normally, this is the pump overrun phase — completely expected behaviour. No action is needed. Only proceed further if the flashing is persistent, the boiler is cutting out, or performance is poor.

  2. Check your gas supply is on DIY safe

    Confirm that other gas appliances in your home (such as a gas hob) are working normally. If they are not, contact your gas supplier rather than attempting a boiler reset.

  3. Check and top up system pressure if needed DIY safe

    Look at the pressure gauge on the boiler — it should read between 1.0 and 1.5 bar when the system is cold. If it reads below 1 bar, use the filling loop to slowly top up the pressure until it sits around 1.2 bar, then close the filling loop valve fully. Refer to your boiler's manual for the location of the filling loop on your specific model.

  4. Bleed the radiators to remove trapped air DIY safe

    Starting with the radiator furthest from the boiler, use a radiator bleed key to open the bleed valve slightly until you hear hissing air escaping. Once a steady trickle of water appears, close the valve. Work through all radiators. Afterwards, recheck system pressure and top up again if it has dropped.

  5. Reset the boiler DIY safe

    On most Glow-Worm models, turn the central heating control knob to the reset position (marked with a power or reset symbol), hold for a few seconds, then return it to your desired temperature setting. On some models you press and hold the power button for around five seconds until a symbol flashes on screen. Allow the boiler to complete a full start-up cycle. Do not reset more than two or three times — repeated resets without identifying the cause can mask a developing fault or cause further damage.

  6. Check whether overheating is linked to sludge or restricted flow DIY safe

    If the boiler repeatedly cuts out on high temperature and you can hear a kettling or rumbling noise from the heat exchanger, sludge or limescale build-up is likely. Do not continue resetting the boiler — sustained overheating can permanently damage the heat exchanger. Note any symptoms to report to your engineer. A professional powerflush and fitting of a magnetic system filter is the appropriate remedy.

  7. Call a Gas Safe registered engineer to diagnose and repair Gas Safe engineer

    If the fault persists after the homeowner checks above, an engineer will need to test the NTC thermistor(s) and wiring with a multimeter, inspect the heat exchanger and pump, and assess the PCB if required. Thermistor replacement, pump replacement, and powerflushing are all tasks that must be carried out by a qualified professional. When booking, describe the flashing behaviour, how often the boiler cuts out, and any noises you have noticed.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £100–£300, depending on the underlying cause.

Frequently asked questions

Is the temperature flashing on my Glow-Worm boiler always a fault?

No — in many cases it is entirely normal. When the boiler reaches its set flow temperature the burner shuts off, but the pump continues to run for a short period to circulate residual heat. During this pump overrun phase the temperature display can flash or show a lower reading such as 30°C. If your heating and hot water are working properly and the flashing stops within a few minutes, there is nothing wrong. It is only worth investigating further if the boiler is cutting out repeatedly, performance has dropped, or the flashing never seems to stop.

How much does it cost to fix a temperature sensor fault on a Glow-Worm boiler?

Replacing an NTC thermistor on a Glow-Worm boiler typically costs between £100 and £175 including labour, making it one of the more affordable boiler repairs. If the root cause turns out to be a sludge-blocked heat exchanger requiring a powerflush, expect to pay £300–£600 depending on the size of the system. A circulation pump replacement usually falls in the £180–£280 fitted range. In rare cases where the PCB is at fault, parts and labour can reach around £400–£500 — if that is the case it is worth comparing the cost against a new boiler installation.

Can I fix a flashing temperature fault myself?

There are a few safe checks a homeowner can carry out: verifying the gas supply is on, topping up system pressure to between 1.0 and 1.5 bar via the filling loop, bleeding radiators to remove trapped air, and resetting the boiler up to two or three times. Beyond that, any internal work — including testing or replacing the thermistor, inspecting the pump, or working on the PCB — must be done by a Gas Safe registered engineer. Attempting these yourself is unsafe and could invalidate your boiler warranty or home insurance.

Why does my Glow-Worm boiler keep cutting out on temperature even after a reset?

If the boiler resets and then cuts out again on temperature repeatedly, a simple reset is not solving the underlying problem. The most likely culprits are a failing NTC thermistor sending false readings, restricted water flow caused by sludge or limescale in the heat exchanger, or a weakening circulation pump that cannot move water quickly enough. Continuing to reset without investigation risks permanent heat exchanger damage. Book a Gas Safe engineer to diagnose the root cause — describe how frequently it cuts out and whether you hear any kettling or gurgling noises, as this will help them narrow down the fault quickly.

Affected models: Glow-Worm Betacom, Glow-Worm Betacom 4, Glow-Worm Energy, Glow-Worm Ultimate, Glow-Worm Flexicom, Glow-Worm 30C, Glow-Worm 30HXi

Last reviewed 2 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →