Glow-worm Temperature 60 Flashing Fault Code: Causes, Fixes & Repair Costs

What does the Glow-worm Temperature 60 Flashing fault code mean?

On the Glow Worm Betacom C range, a flashing '60' on the display is the boiler's way of telling you that system water pressure has dropped below the safe operating threshold — specifically below 0.5 bar. At this point the boiler shuts down to protect the heat exchanger from running without enough water (sometimes called a 'dry fire'). If pressure falls further to below 0.3 bar, the display shows 0.0 bar and the boiler switches off completely. This is not an overheating or sensor fault — those are different codes on the same boiler (for example, Temperature 80 flashing indicates an overheat or open-circuit sensor issue, and Temperature 90 flashing relates to flame or gas failure). The Temperature 60 flashing code is purely a low-pressure lockout, and in the majority of cases it can be resolved by a homeowner topping up the system via the filling loop.

Lockout — engineer likely Some DIY checks possible 1 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Check the pressure gauge reading DIY safe

    Locate the pressure gauge, either a dial on the front of the boiler or a digital reading on the display. A healthy cold-system pressure is 1 to 1.5 bar. If it reads below 0.5 bar (or shows 0.0 bar), that confirms the Temperature 60 fault is pressure-related and you should proceed to top up.

  2. Top up system pressure using the filling loop DIY safe

    Make sure the boiler is switched off and the system is cold before you start. Find the filling loop — usually a short silver or grey braided hose with one or two valves, located beneath or behind the boiler. Slowly open the valve (or both valves if there are two) and watch the pressure gauge rise. Stop when the gauge reads between 1 and 1.5 bar. Close the valve(s) firmly. Never let the pressure exceed 2 bar on a cold system.

  3. Reset the boiler DIY safe

    On the Betacom C, turn the central heating control knob to the reset position (marked with a power symbol). Hold or leave it there for at least 30 seconds, then turn it back to your desired temperature setting. The boiler should attempt to fire up. Only reset the boiler two or three times at most — repeated resets without fixing the underlying cause can cause further damage.

  4. Monitor pressure over the following 24–48 hours DIY safe

    After topping up, keep an eye on the pressure gauge over the next day or two. If pressure holds steady between 1 and 1.5 bar, a one-off drop (perhaps after bleeding radiators) was the cause and no further action is needed. If the pressure falls again, something is actively losing water from the system.

  5. Inspect for visible leaks DIY safe

    Without opening the boiler casing, walk around the system and look for damp patches around radiator valves, pipe joints, and the boiler's external connections. Also check outside for water dripping from the PRV discharge pipe — a weeping PRV is a common culprit. Do not attempt to repair any leaks yourself; simply note the location to tell your engineer.

  6. Call a Gas Safe registered engineer if pressure keeps dropping or a leak is found Gas Safe engineer

    If the pressure drops again within a few days of topping up, or if you have spotted a leak, a weeping PRV discharge, or if you suspect the expansion vessel has failed, you need a Gas Safe registered engineer to diagnose and repair the fault. Do not keep topping up and resetting as a long-term workaround — persistent low pressure indicates an underlying problem that will worsen over time and could damage the heat exchanger.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £100–£300, depending on the underlying cause.

Frequently asked questions

Can I fix the Glow Worm Temperature 60 flashing fault myself?

In most cases, yes — at least initially. If the pressure has simply dropped over time or after bleeding radiators, topping up the system via the filling loop to between 1 and 1.5 bar and then resetting the boiler is a safe DIY task that costs nothing. However, if the pressure drops again within a day or two, or you spot a leak, you will need a Gas Safe registered engineer to find and fix the root cause.

How often should I need to top up my boiler pressure?

A well-maintained sealed system should rarely need topping up — perhaps once or twice a year at most as tiny amounts of dissolved air are released over time. If you find yourself topping up every few weeks, or if the pressure drops noticeably within hours of topping up, there is almost certainly a leak or a failing component (such as the expansion vessel or PRV) that needs professional attention.

What does it cost to fix a low-pressure fault on a Glow Worm Betacom C?

If you can top up the pressure yourself, it costs nothing. If an engineer is needed — for example to repair a leak, replace a PRV, or re-charge or replace the expansion vessel — most people pay between £100 and £300 including labour and parts. PRV replacement typically falls in the £100–£180 range, and expansion vessel work is usually £150–£300 for a standard job. More complex repairs such as a heat exchanger leak or extensive pipework work can cost considerably more, but these are uncommon causes of this particular fault code.

Is the Temperature 60 flashing code the same as a Temperature 80 or Temperature 90 fault?

No — these are three distinct faults on the Betacom C. Temperature 60 flashing means low system pressure. Temperature 80 flashing points to an overheat condition or an open-circuit temperature sensor. Temperature 90 flashing indicates a flame or gas supply failure. If your display shows 80 or 90 rather than 60, the cause and fix will be different, and you should search for that specific code.

Affected models: Glow Worm Betacom C

Last reviewed 2 July 2026 · verified by our team.