Sime AL 89 Fault Code: Causes, Fixes & Repair Costs

What does the Sime AL 89 fault code mean?

AL 89 on a Sime boiler means the combustion feedback signal is unstable: the flame-sensing signal the combustion controller uses to regulate the burn is fluctuating too much to control against. These boilers do not just detect that a flame exists — they continuously read its quality through the detection electrode and adjust the gas/air mixture in response. When that feedback becomes noisy or erratic, closed-loop control is impossible and the boiler stops. Sime's checklist is the combustion family's usual suspects: the ignition/detection electrode first, then the flue for blockage, the air diaphragm and the gas calibration — because each of those can make a real flame genuinely unstable, or make a stable flame look unstable to a worn electrode.

Lockout — engineer likely May need a Gas Safe engineer 5 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Glance at the flue terminal DIY safe

    The one safe external check: look for obstruction at the terminal. Everything else on this code is combustion-side work.

  2. Reset once with the OK/RESET button DIY safe

    Hold the OK RESET button for more than 3 seconds. Sime allows a maximum of six consecutive resets before locking out on AL 28, so if the code returns after one or two attempts, stop and book an engineer.

  3. Have a Gas Safe registered engineer work through the combustion-control checks Gas Safe engineer

    Sime's documented checklist for the combustion-control faults covers the ignition/detection electrode (condition, position and earthing), the flue inlet and outlet for blockage, the air diaphragm, the gas calibration and supply pressure, and bleeding air from the gas circuit where relevant. After rectification the engineer reruns the automatic self-calibrating procedure and confirms combustion with a flue-gas analysis.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £100–£350, depending on the underlying cause.

Frequently asked questions

What does AL 89 mean on my Sime boiler?

The flame-quality signal the combustion controller relies on has become too unstable to control against, so the boiler stops. The usual cause is a worn detection electrode; a disturbed flue, a marginal gas/air mixture or a noisy sensing lead produce the same symptom. It is an engineer diagnosis along Sime's documented checklist.

Is the flame actually unstable, or just the reading?

Either — and that is exactly what the engineer determines. A worn electrode makes a good flame look bad; a blocked flue or drifted mixture makes the flame genuinely bad. The checklist (electrode, flue, diaphragm, calibration) separates the two.

How much is the typical fix?

Most AL 89 cases end with a new electrode and a recalibration — the lower half of £100–£350. Flue remediation or valve/board involvement pushes higher. Regional prices vary; get a written quote.

Affected models: Sime Murelle One HE 25, Sime Murelle One HE 30, Sime Murelle One HE 35, Sime Murelle Pro HE MkII, Sime Brava One HE

Last reviewed 25 August 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Sime AL 89 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →