Sime AL 92 Fault Code: Causes, Fixes & Repair Costs

What does the Sime AL 92 fault code mean?

AL 92 on a Sime boiler means the combustion controller has reached the maximum air correction available (at the minimum flow rate) — the closed-loop system has trimmed the air side of the mixture as far as its authority allows and still cannot bring combustion to target at low output. Running out of correction range is diagnostic in itself: something has shifted the combustion so far from baseline that the trim cannot bridge it. Sime's checklist is the standard combustion set — ignition/detection electrode, flue outlets, air diaphragm, gas calibration — since a worn electrode, a restricted air path, a degraded diaphragm or a drifted baseline are the four ways a boiler drifts to the edge of its correction authority.

Lockout — engineer likely May need a Gas Safe engineer 5 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Check the flue terminal externally DIY safe

    A visual check for obstruction, especially in winter. No other user-side action exists for this code.

  2. Reset once with the OK/RESET button DIY safe

    Hold the OK RESET button for more than 3 seconds. Sime allows a maximum of six consecutive resets before locking out on AL 28, so if the code returns after one or two attempts, stop and book an engineer.

  3. Have a Gas Safe registered engineer work through the combustion-control checks Gas Safe engineer

    Sime's documented checklist for the combustion-control faults covers the ignition/detection electrode (condition, position and earthing), the flue inlet and outlet for blockage, the air diaphragm, the gas calibration and supply pressure, and bleeding air from the gas circuit where relevant. After rectification the engineer reruns the automatic self-calibrating procedure and confirms combustion with a flue-gas analysis.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £100–£380, depending on the underlying cause.

Frequently asked questions

What does AL 92 mean on my Sime boiler?

The combustion controller has used all its air-correction range at minimum output and still cannot hit its combustion target — so it stops. It means combustion has drifted a long way from baseline: typically an air-path restriction, an ageing diaphragm or electrode, or a calibration that no longer fits. An engineer works Sime's checklist and recalibrates.

Why does the manual mention minimum flow rate?

Low-output combustion is where the mixture is most delicate and where air-side problems bite first — the controller's correction authority is exhausted there before it fails at full rate. That is why the fault names the minimum-rate condition.

Will it come back after repair?

Not if both halves are done: fix the physical cause and rerun the self-calibration so the controller starts from a true baseline with full correction authority restored. Skipping the recalibration invites a repeat.

Affected models: Sime Murelle One HE 25, Sime Murelle One HE 30, Sime Murelle One HE 35, Sime Murelle Pro HE MkII, Sime Brava One HE

Last reviewed 25 August 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Sime AL 92 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →