Sime AL 90 Fault Code: Causes, Fixes & Repair Costs

What does the Sime AL 90 fault code mean?

AL 90 on a Sime boiler means the combustion controller cannot reach its combustion set point: the closed-loop system that trims the gas/air mixture has driven its correction as directed, but the measured combustion never arrived at the target. The boiler stops because a controller that cannot reach its set point is either working against a physical obstruction (flue restriction, gas starvation), reading through a degraded sensor (electrode), or trimming against a baseline that no longer matches the hardware (calibration). Sime's remedy list mirrors this: electrode, flue outlets, air diaphragm, gas calibration — with the automatic self-calibrating procedure rerun once the physical cause is corrected. AL 93 is a closely related variant of the same failure.

Lockout — engineer likely May need a Gas Safe engineer 5 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Check the flue terminal externally DIY safe

    Look for obstruction — the only user-safe check on a combustion-reach fault.

  2. Reset once with the OK/RESET button DIY safe

    Hold the OK RESET button for more than 3 seconds. Sime allows a maximum of six consecutive resets before locking out on AL 28, so if the code returns after one or two attempts, stop and book an engineer.

  3. Have a Gas Safe registered engineer work through the combustion-control checks Gas Safe engineer

    Sime's documented checklist for the combustion-control faults covers the ignition/detection electrode (condition, position and earthing), the flue inlet and outlet for blockage, the air diaphragm, the gas calibration and supply pressure, and bleeding air from the gas circuit where relevant. After rectification the engineer reruns the automatic self-calibrating procedure and confirms combustion with a flue-gas analysis.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £100–£380, depending on the underlying cause.

Frequently asked questions

What does AL 90 mean on a Sime boiler?

The self-regulating combustion system tried to steer the burn to its target and could not get there, so the boiler stopped. The blockers are physical (flue restriction, weak gas supply), sensory (worn electrode) or calibration (stale baseline) — Sime's checklist covers all four, finishing with a rerun of the self-calibration.

Is AL 90 the same as AL 93?

They are variants of the same 'combustion set cannot be reached' failure, distinguished internally by the controller. For diagnosis and repair they are treated identically — same checklist, same recalibration afterwards.

Can cold weather trigger this?

Indirectly, yes — winter brings iced terminals (air-path restriction) and peak gas demand (supply pressure dips), both of which can stop the set point being reached. The engineer's working-pressure and flue checks catch each.

Affected models: Sime Murelle One HE 25, Sime Murelle One HE 30, Sime Murelle One HE 35, Sime Murelle Pro HE MkII, Sime Brava One HE

Last reviewed 25 August 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Sime AL 90 — one step done already.