Vokera A09 Fault Code: Causes, Fixes & Repair Costs

What does the Vokera A09 fault code mean?

The A09 code on a Vokera boiler signals one of two things depending on the model and generation. Most commonly, it points to a fault with the flue thermistor — the sensor that monitors the temperature of exhaust gases leaving the boiler — or indicates that an internal condensing-hours counter has reached a threshold, telling you the boiler needs attention. On some Vokera models, A09 can alternatively mean the control board has detected a flame signal at a moment when no flame should be present (known as false flame detection), which may point to an electrical fault, a faulty flame sensor, or flue gas recirculation. In either case, the boiler will typically lock out to protect itself, and a reset alone may not resolve the underlying problem.

Lockout — engineer likely May need a Gas Safe engineer 7 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Check the flue terminal for visible blockages DIY safe

    Go outside and look at where the flue exits the building. Check for obvious obstructions such as leaves, debris, bird nests, or ice covering the terminal grille. Do not attempt to dismantle or reposition the flue — this is gas work. If something is visibly blocking the opening from the outside, contact an engineer.

  2. Thaw a frozen condensate pipe if the weather is freezing DIY safe

    If outdoor temperatures are at or below zero, your external condensate pipe (usually a white or grey plastic pipe running outside, often at the side or rear of the property) may be frozen. Pour warm — not boiling — water gently along its length to thaw it. Once thawed, try resetting the boiler. Lagging the pipe afterwards will help prevent a repeat.

  3. Check and top up system pressure DIY safe

    Look at the pressure gauge on the boiler. It should read between 1.0 and 1.5 bar when cold. If it reads below 1.0 bar, use the filling loop (two small valves beneath the boiler connected by a short braided hose) to slowly bring the pressure up to around 1.2–1.5 bar, then close both valves firmly.

  4. Reset the boiler DIY safe

    On most Vokera models, turn the mode selector to the OFF/RESET position, hold briefly, then return it to your desired setting (heating and hot water, or hot water only). Allow the boiler a few minutes to complete its startup sequence. If A09 clears and the boiler runs normally, monitor it over the next day. If the code returns, do not continue resetting — proceed to call an engineer.

  5. Have a Gas Safe engineer inspect the flue thermistor and wiring Gas Safe engineer

    An engineer will use a multimeter to check the thermistor's resistance against the manufacturer's specification and inspect the sensor wiring harness for corrosion, chafing, or loose connections. A faulty thermistor is straightforward to replace once diagnosed. This step is required if the reset did not clear the fault.

  6. Have the condensing-hours counter checked and reset (if applicable) Gas Safe engineer

    If the boiler is due a service and the A09 relates to the internal condensing counter, the engineer will carry out a full service — cleaning heat exchanger surfaces, checking combustion, inspecting seals — and then reset the counter using the boiler's diagnostic interface. A user reset alone will not clear a counter-triggered A09.

  7. Have the flame detection circuit inspected if false flame is suspected Gas Safe engineer

    Where A09 on your model indicates false flame, the engineer will inspect the flame sensor rod for contamination and test the gas valve for internal leakage. They will also check for flue gas recirculation by examining flue routing and terminal position. The PCB may be tested last if all other components prove sound.

  8. Call a Gas Safe registered engineer if the fault persists or returns Gas Safe engineer

    If A09 returns after completing the checks above, the boiler needs professional diagnosis. Do not attempt further resets. Contact a Gas Safe registered engineer and quote the fault code so they can arrive prepared with the likely parts. You can verify any engineer's Gas Safe registration at gassaferegister.co.uk.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £120–£350, depending on the underlying cause.

Frequently asked questions

Can I fix a Vokera A09 fault myself?

The preliminary checks — looking at the flue terminal for blockages, thawing a frozen condensate pipe, topping up system pressure, and resetting the boiler — are all safe for a homeowner to carry out. However, replacing the flue thermistor, working on the PCB, inspecting the gas valve, or resetting a service counter all require a Gas Safe registered engineer. Attempting gas-related work without registration is illegal in the UK and can be dangerous.

How much does it cost to fix a Vokera A09 fault code in the UK?

For the most common repair — flue thermistor replacement including labour — expect to pay roughly £120 to £250. If the fault turns out to be a full service requirement linked to the condensing-hours counter, a service visit typically costs £80 to £150. If the PCB is the root cause, parts alone can reach £180 to £250 plus labour, pushing the total to £300 or more. Most households with an A09 fault end up spending in the £120–£350 range.

Why does my Vokera A09 code keep coming back after I reset it?

A reset only clears the lockout — it does not fix the underlying fault. If A09 returns repeatedly, the most likely explanations are a thermistor that is failing intermittently, a condensing-hours counter that has genuinely hit its limit and needs a full service reset, or a wiring issue that appears and disappears with vibration. Repeated resets without fixing the root cause can mask a developing problem, so book an engineer rather than continuing to reset.

Is A09 the same fault on all Vokera boiler models?

Not quite. The A09 code carries slightly different meanings across Vokera's range. On most models it refers to a flue thermistor or flue thermistor counter fault. On some older or alternative Vokera models it can indicate false flame detection — where the PCB sees an ionisation signal when no flame should be present. If you are unsure which interpretation applies to your specific boiler, check the model number on the appliance data plate and refer to your installation manual, or ask your engineer to confirm before ordering parts.

Affected models: Vokera Linea, Vokera Mynute, Vokera Unica, Vokera Compact, Vokera Vision, Vokera Syntesi, Vokera Easi-Heat

Last reviewed 1 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.