Vokera A11 Fault Code: Causes, Fixes & Repair Costs

What does the Vokera A11 fault code mean?

The A11 code on a Vokera boiler indicates a 'false flame' condition — the boiler's flame detection system is registering a flame signal at a point when the burner should not be alight. Because the control system cannot reconcile an unexpected flame signal with normal operation, it triggers a safety lockout to protect your home. This is not a minor nuisance fault: any fault involving an unexpected flame signal must be taken seriously and investigated by a Gas Safe registered engineer before the boiler is returned to regular use.

Lockout — engineer likely May need a Gas Safe engineer 7 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Switch the boiler off and wait 30 seconds, then attempt a single reset DIY safe

    Power the boiler down fully at the programmer or boiler switch, wait about 30 seconds, then press the reset button as described in your Vokera manual. Watch the display — if the A11 code returns within a few minutes, do not reset again. One cautious reset is reasonable; repeated resets on a false-flame fault are not safe and could allow uncontrolled gas flow to go unnoticed.

  2. If A11 returns immediately, turn off the gas supply DIY safe

    If the lockout reappears as soon as the boiler tries to fire, turn off your gas supply at the meter and do not attempt to restart the boiler. Contact a Gas Safe registered engineer straight away. Do not leave the boiler running in this state.

  3. Call a Gas Safe registered engineer for diagnosis Gas Safe engineer

    A qualified engineer will carry out a systematic inspection covering the ionisation probe (cleaning or replacing it if contaminated), the gas valve (checking for sticking, leakage, or wear), the PCB (testing signal outputs and comparing them against expected values), and the wiring harness (looking for corrosion, damage, or poor connections). Do not attempt to inspect or adjust the gas valve or PCB yourself — this work requires Gas Safe registration and specialist equipment.

  4. Have the faulty component repaired or replaced Gas Safe engineer

    Once the engineer has identified the root cause, they will advise on repair or replacement. For older Vokera boilers, ask the engineer to assess the overall condition of other expensive components (heat exchanger, pump, PCB) at the same time — if several parts are showing significant wear, a new boiler may represent better value than investing in multiple repairs.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £120–£380, depending on the underlying cause.

Frequently asked questions

Is the Vokera A11 fault dangerous?

It should be treated as urgent, yes. The boiler has locked out because it detected a flame signal when no flame should be present — which could indicate gas is passing through the valve when it shouldn't be. Do not repeatedly reset the boiler to force it back into operation. Turn off the gas at the meter if the fault returns immediately after a reset, and call a Gas Safe engineer the same day.

Can I reset my Vokera boiler to clear the A11 code?

One careful reset is acceptable — power the boiler off for 30 seconds, then reset and watch what happens. If the A11 code clears and the boiler runs normally, monitor it closely over the next day or two. If the code returns straight away or keeps coming back, stop resetting and call an engineer. Repeated resets on a false-flame fault are not safe.

How much does it cost to fix a Vokera A11 fault?

Most repairs fall in the £120–£380 range, depending on which component is at fault. Replacing the ionisation probe is typically £100–£150 all-in. A gas valve replacement is usually £275–£350 including parts and labour. For a straightforward wiring or connection repair the cost is often towards the lower end. PCB replacement can be significantly more — sometimes £450–£550 — so if the PCB is the cause on an older boiler, it is worth discussing with your engineer whether a new boiler makes more financial sense.

Why is my Vokera boiler showing A11 when there's no demand for heat?

The most likely explanation is that the gas valve is sticking slightly open, allowing a trickle of gas through when the valve should be fully closed. This produces a small residual flame that the ionisation probe detects. A faulty or dirty probe can also send a false signal independently of the valve. Either way, a Gas Safe engineer needs to test both components to identify which is responsible.

Affected models: Vokera Unica, Vokera Compact, Vokera Excell, Vokera Vision, Vokera Flowmatic, Vokera Mynute, Vokera Linea

Last reviewed 1 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Vokera A11 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →