Biasi E99 Fault Code: Causes, Fixes & Repair Costs

What does the Biasi E99 fault code mean?

The E99 fault code on Biasi boilers indicates that the PCB (printed circuit board) — the electronic control unit that governs every function of the boiler — is reporting that it is not configured or has lost its programmed settings. In practical terms, the boiler's 'brain' either does not recognise a valid configuration, has had its settings wiped (for example after a power disruption or board replacement), or the board itself has developed a hardware fault. Until the PCB is correctly configured or replaced, the boiler will not operate. This fault appears across several Biasi models including the Rinnova combi and Rinnova system boiler ranges. Because the fix involves accessing internal electronics and, in most cases, entering a protected engineer parameter mode, this is strictly an engineer-only fault — it is not resolvable by a homeowner.

Lockout — engineer likely May need a Gas Safe engineer 5 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Check that your gas supply is working DIY safe

    Before assuming the boiler electronics are at fault, confirm that other gas appliances in your home (hob, fire) are working normally. If there is no gas supply, contact your gas network operator. This step rules out a simple supply interruption that could have caused the boiler to lose power unexpectedly.

  2. Check the boiler's system pressure DIY safe

    Look at the pressure gauge on the boiler — it should sit between 1.0 and 1.5 bar when cold. If it reads below 0.8 bar, top up via the filling loop following your boiler's user guide. Low pressure alone will not cause E99, but it is good practice to ensure the system is in the correct state before an engineer visits.

  3. Attempt a single boiler reset DIY safe

    Press and hold the reset button on the boiler's control panel as described in your user guide. Wait for the boiler to restart and monitor it for 10–15 minutes. If E99 clears and does not return, keep an eye on it over the next day or two. If the code comes back, do not keep resetting — repeated resets will not fix an underlying electronic fault and may mask important diagnostic information for the engineer.

  4. Check for any obvious signs of a water leak inside the boiler casing DIY safe

    With the boiler off and cooled down, remove the front casing panel if you are comfortable doing so (this does not involve gas or electrical work — simply unclipping or unscrewing the cover). Look for water staining, corrosion, or damp patches near the PCB, which is typically a green or grey circuit board mounted near the top or front of the appliance. If you see evidence of a leak, note where it appears to be coming from and report this to the engineer — do not attempt to repair it yourself.

  5. Contact a Gas Safe registered engineer to diagnose and resolve the fault Gas Safe engineer

    Resolving E99 requires an engineer to access the boiler's protected parameter setting mode (a key-hold sequence that brings up the 'HiS' menu on the display) and work through the configuration procedure. If reconfiguration does not resolve the fault, the engineer will test the PCB and associated wiring before deciding whether a board replacement is needed. Always ask your engineer to verify there is no underlying cause — such as a wiring fault, water ingress, or failing sensor — before fitting a new PCB, as replacing the board without addressing the root cause may result in the same fault recurring. If your Biasi boiler is within its warranty period (typically five to seven years depending on model), contact Biasi UK directly before authorising any paid repair.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £120–£400, depending on the underlying cause.

Frequently asked questions

Can I fix Biasi E99 myself by resetting the boiler?

A reset is unlikely to clear E99 permanently because the code indicates the PCB has lost its configuration or has failed — neither of which a reset can address. You can try one reset to see if the fault clears temporarily, but if E99 returns you will need a Gas Safe registered engineer. Do not reset the boiler repeatedly, as this does not constitute a repair and can delay a proper diagnosis.

How much does it cost to fix a Biasi E99 fault in the UK?

If the PCB simply needs re-programming (no parts required), most engineers will charge their standard call-out and labour rate, typically £120–£180 all in. If the PCB needs to be replaced, you are looking at roughly £200–£400 including parts and labour for most Biasi models, though prices in London and the South East tend to sit at the higher end. In rare cases where a board is difficult to source or the boiler is an older model, costs can exceed this — if a quote comes in above £450 or so, it is worth comparing it against the cost of a new boiler, particularly if the appliance is more than eight to ten years old.

Why has E99 appeared after my boiler's PCB was just replaced?

This is actually the most common scenario for E99. A replacement PCB is supplied in an unconfigured state and must be programmed to the specific boiler model before it will operate. The configuration process involves entering a protected engineer menu (triggered by holding two control keys for five seconds until 'HiS' shows on the display) and stepping through the required parameters. If the engineer who fitted the board did not complete this procedure, or if the programming was interrupted, E99 will show. Contact the engineer who carried out the replacement — this should be resolved under their workmanship warranty at no additional cost to you.

Is it worth repairing a Biasi boiler showing E99, or should I replace it?

If your Biasi boiler is relatively new (under seven years old) and in otherwise good condition, a PCB reconfiguration or replacement is usually worthwhile and can restore many more years of reliable service. If the boiler is older, has a history of faults, or the repair quote is approaching or exceeding half the cost of a new boiler installation (typically £2,000–£3,500 for a new combi), replacement often makes more financial sense. Also remember that Biasi boilers carry a manufacturer's warranty of five to seven years depending on the model — if yours is still in warranty, contact Biasi UK before agreeing to any paid repair.

Affected models: Biasi Rinnova Combi, Biasi Rinnova System, Biasi Riva Advance, Biasi Riva Plus M90E, Biasi Riva Compact

Last reviewed 8 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Biasi E99 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →